Turnkey revamping of the BOF Shop gas cleaning system
Project
Detail design documentation
Revamping and supply of the gas cleaning system, waste heat boiler, ID fan complete with an electric motor
Composition of work
→
Swipe
←
Gas flow 280 m3/h
Dust content downstream the BOF - 120 g/m3
Dust content after gas cleaning - less that 50 g/m3
Using a grease lubrication system for roller bearings of the ID fan and the motor and elimination of liquid lubrication made it possible to significantly reduce negative effect on the environment, as well as operating costs.